  C7  
For models with no programming or with 0-10v programming (option “C6”): 
  Voltage Monitor Terminal:  Permits remote monitoring of output voltage, stepped down by a ratio of 10:1 (for 3.3v to 90v models) or 100:1 (for 100v to 150v models). Accuracy is 0.5% of maximum rated output voltage.Current Monitor Terminal:  For models with greater than 10 amps output current: permits remote monitoring of output current, stepped down by a ratio of 100 mV/Amp (accuracy is 1% of maximum rated output current). For models with less than 10 amps output current: permits remote monitoring of output current, stepped down by a ratio of 1000 mV/Amp.
  (Accuracy is 1% of maximum rated output current or ±15 mA, whichever is greater.)
  For models with 0-5v programming (option “C5”): 
  Voltage Monitor Terminal:  Permits remote monitoring of output voltage, stepped down by a ratio of 10:1 (for 3.3v to 45v models) or 100:1 (for 48v to 150v models). Accuracy is 0.5% of maximum rated output voltage.Current Monitor Terminal:  For models with greater than 45 amps output current: permits remote monitoring of output current, stepped down by a ratio of 10 mV/Amp. For models with from 5 amps to 45 amps output current: permits remote monitoring of output current, stepped down by a ratio of 100 mV/Amp. For models with less than 4.5 amps output current: permits remote monitoring of output current, stepped down by a ratio of 1000 mV/Amp. (Accuracy is 1% of maximum rated output current or ±15 mA, whichever is greater.)
  (When monitoring the output voltage and/or current by means of the monitor terminals, the use of an instrument having an input impedance of at least 10 megohms is recommended.)