Low Profile 2
Switching Regulated Power Supplies (to 900 watts)
Power Factor Correction and Universal Input
AC-DC or DC-DC
single output
- Five Year Warranty
-
SPECIFICATIONS
Input Voltage: 90-265 VAC, 49-420 Hz, single phase, or
110-350 Vdc.
AC input (maximum): 8A (LP2B case), 12A (LP2 case)
DC input (maximum): 7A (LP2B case), 10A (LP2 case)
DC input may be connected without regard to polarity.
Inrush current: Cold start, (thermistor limiter) 33A peak @115 VAC (typical); 65A peak @ 230 VAC (typical). (Suitable for use with most ground fault protected circuits.)
Startup Time: 800 ms (typical).
Input Undervoltage: An input of less than 90 VAC will not damage power supply.
Power Factor: 0.99 (typical) at 115 VAC, 60Hz and full load. Complies with EN61000-3-2.
Total Harmonic Distortion: ≤10% (typical) at 115 VAC, 60Hz and full load. Complies with EN61000-3-2, Class A.
Regulation (in constant voltage mode): Line Regulation: ±0.05% or 5 mV, whichever is greater. Load Regulation: ±0.05% or 5 mV, whichever is greater.
Regulation, Ripple (in constant current mode): Line Regulation: ±0.2% or 30 mA. Load Regulation: ±0.5% or 100 mA. Current Ripple: 0.5% rms.
Regulation, Ripple (in 'N+1' or 'P' mode): Line Regulation: ±0.1% or 50 mV, whichever is greater. Load Regulation: ±0.1% or 50 mV, whichever is greater. Ripple: 2x rating in table.
Ambient Operating Temperature: 20 to +71°C. Derate output power at 1%/°C above 40°C.
Temperature Coefficient (after 30 minute warm-up): Voltage mode; ±0.02%/°C (typical). Current mode; ±0.1%/°C (typical).
Drift (voltage mode or current mode): ±0.1% (typical) over 8 hours, after 30 minute warmup.
Storage Temperature: 40 to +85°C.
Holdup Time: 20 ms minimum with full load.
Transient Response: 3 ms to return to ±1% of output setting. Maximum of ±3% output excursion following a load step change from 50% to 100%.
Efficiency: See table. (Typical, at 115 VAC, with full load.)
Polarity: Output is floating and may be used in either polarity.
Remote Sensing: Compensates up to 0.5 Vdc drop per output line (or within the limits of the output voltage adjustment range).
Output Adjustment: Voltage and current output adjustments are located on the front. Output adjustment may also be controlled by using remotely located potentiometers.
Voltage Monitor Terminal: Permits remote monitoring of output voltage, stepped down by a ratio of 10:1 (for 5v to 90v models) or 100:1 (for 100v to 125v models). Accuracy is 0.5% of maximum rated output voltage.
For models with 0-5v programming option "C5": Permits remote monitoring of output voltage, stepped down by a ratio of 10:1 (for 5v to 90v models) or 100:1 (for 100v to 125v models). Accuracy is 0.5% of maximum rated output voltage.
Current Monitor Terminal: For models with greater than 10 amps output current: permits remote monitoring of output current, stepped down by a ratio of 100 mV/Amp (accuracy is 3% of maximum rated output current). For models with less than 10 amps output current: permits remote monitoring of output current, stepped down by a ratio of 1000 mV/Amp (accuracy is 3% of maximum rated output current).
For models with 0-5v programming option "C5": For models with greater than 45 amps output current: permits remote monitoring of output current, stepped down by a ratio of 10 mV/Amp (accuracy is 5% of maximum rated output current). For models with less than 45 amps output current: permits remote monitoring of output current, stepped down by a ratio 100 mV/Amp (accuracy is 3% of maximum rated output current).
Overload/Short Circuit Protection: A short or overload forces the power supply into constant current mode, with automatic recovery.
Overvoltage Protection: 15% above rated output voltage.
Thermal Protection: Self-resetting.
Internal Failure Protection: Provided by internal fuse.
Output Enable: Jumper Enable terminal to DC output.
Output Programming (Wide Adjust models): The output voltage and current may be programmed from 0 to full rating by means of control voltage inputs of 0 to +10 Vdc (0 to +5Vdc for models with option "C5"). Voltage mode accuracy: 0.5%. Current mode accuracy: 3% for models with greater than 10 amps output current and 4% for models with less than 10 amps output current. Accuracy percentages do not apply below 5% of output rating.
V ok: When the power supply's output voltage is between -14% ±2% of the minimum rated output voltage and +15% ±2% of the maximum rated output voltage, 'V ok' will be between +3 and +5 Vdc (high). When the output voltage is outside the -14%, +15% window, the 'V ok' voltage will go low (approx 0.5 Vdc). 'V ok' can source 1 mA or sink up to 5 mA.
Output Indicators: Green LED (DC on); Red LED (DC off); Purple LED (Current Mode operation).
Switching Frequency: 110 kHz (typical).
EMI: Tested to comply with the following:
EN55032 Emissions
CISPR 16-2-1 Conducted Class A
CISPR 16-2-3 Radiated Class A
EN5035 Immunity
EN61000-4-3 Electromagnetic Field
EN61000-4-2 Electrostatic Discharge
IEC61000-4-6 RF Disturbances
IEC61000-4-11 Voltage Dips and Interruptions
IEC61000-4-5 Surges, Power Ports
IEC61000-4-4 Electric Fast Transient/Burst
EN61000-3-2 Power Frequency Harmonics
EN61000-3-3 Voltage Fluctuation and Flicker
Dielectric Withstand Voltage | Isolation | |
Input to output: | 4242 Vdc | 300 Vdc |
Input to case: | 2121 Vdc | 300 Vdc |
Output to case: | 750 Vdc | 300 Vdc |
Cooling: 600w (LP2B) Models: Convection cooled. 900w (LP2) Models: Forced-air cooled; air enters rear of power supply and exits from top and front cover. Thermostatically controlled fans run at reduced speed until maximum speed is required.
15Vdc Auxiliary Voltage: +15Vdc ±2% at 100mA.
Mounting: Threaded mounting holes permit mounting to a chassis, cabinet wall or bracket. To mount from the power supply side of the mounting surface use accessory Mounting Kits.