Narrow Profile
	
		(3-Day Power Supply)
		Switching Regulated Power Supplies (to 120 watts)
	AC-DC single output 
		DC-DC (DC input can be used on 230 VAC input models)
- Shipped Within 3 Days
- UL60950, UL508, CE Certified*
- Five Year Warranty
- 
        
- (*Utilizing AC Input Power Only)
SPECIFICATIONS
Input Voltage: 90-132 VAC, 47-420 Hz, single phase. 180-265 VAC input is also available (see Options).
DC Input: Not applicable on 115 VAC models. 
		On 230 VAC models, 200-375 Vdc input can be used. 
		DC input may be connected without regard to polarity.
Inrush current: Cold start, (thermistor limiter) 15A peak @115 VAC; 30A peak @ 230 VAC.
Startup Time: 1 second typical.
Input Undervoltage: An input of less than 90 VAC (180 VAC with "–230" option) will not damage power supply.
Load Regulation: ±0.05% or  5 mV, whichever is greater.
		Line Regulation: ±0.05% or  5 mV, whichever is greater.
Output Voltage Remote Adjustment: The output voltage may be controlled by means of an external 1K potentiometer.
Polarity: Output is floating and may be used in either polarity.
Drift: ±0.1% maximum over 8 hours, after 30 minute warmup.
Temperature Coefficient: ±0.02%/°C (Typical).
Holdup Time: 20 mS minimum.
Transient Response: 3 ms to return to ±1% of output setting. Maximum of ±3% output excursion following a load step change from 50% to 100%.
Remote Sensing: Compensates up to 0.5 volt drop per output line, within the limits of the output voltage adjustment range.
Overload/Short Circuit Protection: Current limiting with automatic recovery.
Overvoltage Protection: Automatic reset.
EMI: Designed to meet FCC Part 15 and EN55022, Class A.
Output Indicator (DC on): Green LED.
Efficiency: See Output Specs. (Typical, at nominal input voltage, with full load.)
Ambient Operating Temperature: 0 to +71°C.
Storage Temperature: –40 to +85°C.
Cooling: Case size WN6A: forced air cooled; air enters rear of power supply and exits from top. Case size WN6B: convection cooled.
Switching Frequency: 100 kHz (Typical).
Dielectric Withstand Voltage Isolation --------------------------------------------- Input to output: 4242 Vdc 300 Vdc Input to case: 2121 Vdc 300 Vdc Output to case: 750 Vdc 300 Vdc
Internal Failure Protection: Provided by internal fuse.
Size and Weight:
Case | Rough | Number of fans | Approx. Size | Dimensions (inches) | on rear panel | Weight -------|---------------------|--------------------|-------------- WN6A 1.7 x 3.5 x 7.9 1 1 lb. 6 oz. ----------------------------------------------------------------- WN6B 1.7 x 3.5 x 7 0 1 lb. 4 oz. ----------------------------------------------------------------- See Drawing for exact dimensions.
Mounting: Threaded mounting holes permit mounting to a chassis, cabinet wall or bracket. To mount from the power supply side of the mounting surface or for DIN rail mounting, use accessory Mounting Kits.
 
                    
                 
											 Made In The USA
                Made In The USA
             
        