2U Switching Regulated Power Supplies

Switching Power Supplies (to 1400 watts)
Power Factor Correction and Universal Input

AC-DC wide adjust output


Input Voltage: 100-265 VAC, 49-420 Hz, single phase. AC Input, max.: 22A (1400W)

Inrush current: Cold start, (thermistor limiter) 66A peak @115 VAC (typical); 130A peak @230 VAC (typical).

Startup Time: 1 second (typical).

Input Undervoltage: An input of less than 100 VAC will not damage power supply.

Power Factor: 0.97 typical at 115 VAC, 60Hz and full load. Complies with EN61000-3-2.

Regulation (in constant voltage mode):
Line Regulation: ±0.1% or 10 mV, whichever is greater.
Load Regulation: ±0.1% or 10 mV, whichever is greater.

Regulation, Ripple (in constant current mode):
Line Regulation: ±0.4% or 60mA.
Load Regulation: ±1% or 200mA. Current Ripple: 1% rms.

Ambient Operating Temperature: 0 to +71°C.

Temperature Coefficient (after 30 minute warm-up):
Voltage mode; ±0.04%/°C (typical).
Current mode; ±0.2%/°C (typical).

Drift (voltage mode or current mode): ±0.2% (typical) over 8 hours, after 30 minute warmup.

Storage Temperature: –40 to +85°C.

Holdup Time: 10mS minimum with full load.

Efficiency: See table. (Typical, at 115 VAC, with full load.)

Polarity: Output is floating and may be used in either polarity, except in programmable/wide adjust models.

Remote Sensing: Compensates up to 0.5 Vdc drop per output line (or within the limits of the output voltage adjustment range).

Output Adjustment: Voltage and current adjustments are located on the front panel.

Overload/Short Circuit Protection: A short or overload forces the power supply into constant current mode, with automatic recovery.

Overvoltage Protection: Latches power supply OFF, reset by momentarily removing AC input power.*

Thermal Protection: Thermostat(s), self-resetting.*

Internal Failure Protection: Provided by internal fuse.

Switching Frequency: 110 kHz (typical).

EMI: Designed to meet FCC Part 15 and EN55022, ClassA.

Dielectric Withstand Voltage       Isolation
Input to output:     4242 Vdc      300 Vdc 
Input to case:       2121 Vdc      300 Vdc 
Output to case:       750 Vdc      300 Vdc 

Cooling: Forced-air cooled. Air enters front of power supply and exits from rear cover. Fan noise rated at 54dB for 1400w models.

Size and Weight:
Case   | Rough                        |  Approx. 
Size   | Dimensions (inches)          |  weight 
2U18     2U x 19" panel, 19.2" deep      19 lb.
2B18     2U x 17" panel, 19.2" deep      19 lb.
See Drawing for exact dimensions

Enable: To enable the DC output, the enable terminal must be tied to the -DC output. An open collector or contact closure can be used.

Output Programming: The output voltage and current may be programmed from 0 to full rating by means of control voltage inputs of 0 to +10 Vdc.

Mounting: Rack Mounting models are designed expressly for mounting in standard 19" wide RETMA cabinet racks. Benchtop models rest on four rubber feet.

*Output may drop to 0v or 1/2 of output set voltage.